Leeson FHP Series Chassis Mount Variable Speed Drives Manual de usuario Pagina 11

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 76
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 10
1
Specifications
1-Phase 1 or 3-Phase Max Continuous AC
Input Output Max Output Amps
Drive (VAC) (VAC) HP Current (AC) In
175318 230 230 ¼ 1.2 3
175319 *115 / 230 230 ¼ 1.2 7 / 3
175320 115 115 ¼ 2.4 7
175321 230 230 ½ 2.4 7
175310 *115 / 230 230 ½ 2.4 10 / 7
175322 115 115 ½ 4.0
10
175323 230 230 1 4.0
10
175311 *115 / 230 230 1 4.0
15 / 10
* Connect only 115 VAC line input to the 115 VAC terminals. Application of 230 VAC line input when set for 115
VAC will result in severe damage to the motor and drive, and possible explosion and injury.
† Derate current by 2% per degree if the operating temperature is above 40°C. Under no circumstances may the
ambient temperature exceed 55° C.
AC Voltage Input Range
175320 & 175322 115 VAC ± 10%, 50/60 Hz single phase
175318, 175321, & 175323 230 VAC ± 10%, 50/60 Hz single phase
175319, 175310, & 175311 115/230 VAC ± 10%, 50/60 Hz single phase
Standard Carrier Frequency 16 KHz
Output Frequency Range 0 – 120 Hz
Adjustable Maximum Output Frequency Range 30 – 120 Hz
Acceleration Time Range 1 – 12 seconds
Deceleration Time Range 1 – 12 seconds
Analog Input Voltage Range (signal must be isolated; S1 [-] to S2 [+]) 0 – 5VDC**
Input Impedance, S1 to S2 ~ 100K ohms
Vibration 0.5G max (20 – 50 Hz)
0.1G max (> 50 Hz)
Weight 1.2 lb
Ambient Operating Temperature Range 10° – 40° C
** An isolation board option that allows for a non-isolated 0 - 5 VDC, 0 - 10 VDC, or 4 - 20 mA input signal is
available (-PCM option). The option board is installed directly above the main board, maintaining the same
footprint and dimensions. Call the factory for more information regarding the -PCM option.
Vista de pagina 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 75 76

Comentarios a estos manuales

Sin comentarios