27
Multiple fixed speeds
Replace the speed adjust potentiometer with series resistors
with a total series resistance of 10K ohms (Figure 14). Add a
single pole, multi-position switch with the correct number of
positions for the desired number of fixed speeds.
Figure 14. Multiple Fixed Speeds