Leeson PWM DC Control: 174299 Manual de usuario Pagina 29

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 35
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 28
24
RUN/JOG Switch
Using a RUN/JOG switch is recommended in applications where quick stopping is not needed and
frequent jogging is required. Use a single pole, two position switch for the RUN/JOG switch, and a
normally closed, momentary operated pushbutton for the JOG pushbutton (see Figure 16). When the
RUN/JOG switch is set to JOG, the motor decelerates to minimum speed. Press the JOG pushbutton
to jog the motor. Return the RUN/JOG switch to RUN for normal operation.
S3
S2
S1
CW
10K OHM
SPEED POT
RUN
JOG
JOG
PUSHBUTTON
Figure 16. RUN/JOG Switch Connection to Speed Adjust Potentiometer
Vista de pagina 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 35

Comentarios a estos manuales

Sin comentarios